Description
The Benchtop Class B Autoclave 45L is a compact steam sterilisation system designed for healthcare and laboratory environments requiring a substantial 45-litre chamber capacity within a benchtop format. Model ST-B45B combines pre-vacuum operation, steam sterilisation, post-vacuum drying and programmable cycle control within one automated system.
With a 105–136°C sterilisation temperature range, 0.23 MPa sterilisation pressure and a stainless steel SUS304 chamber, the unit is designed to process compatible medical instruments, hollow instruments, dressings, rubber items and liquids using dedicated programmes.
A built-in water tank, vacuum pump, steam generator, LCD touchscreen and printer provide an integrated approach to cycle operation and documentation. The 45-litre chamber also provides additional capacity for organisations requiring more processing space than smaller benchtop steriliser models.
What Is a Benchtop Class B Autoclave?
A benchtop autoclave is a steam steriliser designed to provide sterilisation capability within a comparatively compact footprint. Class B systems use vacuum stages as part of the sterilisation process, helping remove air before steam penetration and supporting post-cycle drying.
The ST-B45B uses a three-time pulsed vacuum process. Its automatic operating sequence covers pre-vacuum, heating, sterilisation, steam discharge and post-vacuum drying, with operation monitored through an LCD touchscreen.
For healthcare applications, equipment selection must form part of a properly managed decontamination system. NHS England’s HTM 01-01 provides guidance covering the management and decontamination of reusable surgical instruments in acute healthcare settings.
Key Features of the Benchtop Class B Autoclave 45L
The ST-B45B combines a 45-litre chamber with automated steam sterilisation and drying functions. Its operating temperature can be selected within a 105–136°C range, with a maximum working temperature of 136°C.
Temperature control is provided through a microprocessor-based PID controller, while the specified temperature accuracy is 0.1°C and temperature uniformity is ≤±0.5°C.
The system incorporates a built-in vacuum pump for three pulsed vacuum stages, helping remove air from compatible loads before steam sterilisation. A built-in steam generator is also incorporated into the unit.
Following sterilisation, post-vacuum drying provides an automated drying stage, with a specified drying time of 15 minutes.
45-Litre Chamber Capacity
The Benchtop Class B Autoclave 45L has a chamber measuring Ø316 × 590 mm, providing a comparatively substantial internal capacity while retaining a benchtop configuration.
The external dimensions are 870 × 600 × 520 mm. Healthcare and laboratory procurement teams should consider both the external footprint and required service clearances when assessing installation locations.
The chamber is manufactured from SUS304 stainless steel.
Sterilisation Programmes
The ST-B45B provides dedicated programmes for several different load categories. Verified programmes include:
- Medical instruments
- Luminal instruments
- Dressings
- Rubber
- Liquids
- BD test
- Vacuum test
- Four user-customised programmes
The availability of different programmes allows the operating cycle to be selected according to compatible load requirements.
Cycle selection should always be based on the compatibility of the items being processed, applicable instructions for use and the organisation’s validated decontamination procedures.
Vacuum and Drying Performance
Effective air removal is an important consideration for steam sterilisation because retained air can interfere with steam contact and penetration.
The ST-B45B incorporates a built-in vacuum pump that performs a three-time pulsed vacuum process. The system subsequently provides post-vacuum drying after sterilisation.
NHS England’s HTM 01-01 Part C provides detailed guidance concerning steam sterilisation and the management, testing and maintenance requirements associated with sterilisers used for reusable medical devices.
LCD Touchscreen and Microprocessor Control
Operation is controlled using a microprocessor-based PID temperature controller together with an LCD touchscreen.
This interface enables users to set and monitor the sterilisation process while the system manages the principal stages of the cycle automatically.
The automatic sequence incorporates:
Pre-vacuum → heating → sterilisation → steam discharge → post-vacuum drying.
This integrated approach can support repeatable workflows where the equipment is installed, commissioned, validated and operated according to the appropriate requirements.
Integrated Safety Features
The ST-B45B incorporates several specified safety systems.
Overheat protection automatically interrupts heating and provides audible and visual warning if an overheating condition occurs.
Door interlocking prevents a cycle from beginning when the door is not correctly locked and prevents the door from being opened while the chamber remains pressurised.
Low-water / anti-burning protection interrupts heating and provides audible and visual indication when insufficient water is detected.
A steam pressure safety valve is designed to operate if chamber pressure exceeds its specified limit.
These equipment-level protections do not replace appropriate installation, validation, maintenance, operator training or local decontamination procedures.
Product Specifications
|
Specification |
ST-B45B |
|
Product |
Benchtop Class B Autoclave 45L |
|
Model |
ST-B45B |
|
Capacity |
45 litres |
|
External dimensions (W × D × H) |
870 × 600 × 520 mm |
|
Chamber dimensions |
Ø316 × 590 mm |
|
Chamber material |
SUS304 stainless steel |
|
Sterilisation temperature |
105–136°C |
|
Design temperature |
150°C |
|
Maximum working temperature |
136°C |
|
Temperature accuracy |
0.1°C |
|
Temperature uniformity |
≤±0.5°C |
|
Design pressure |
-0.1 / 0.3 MPa |
|
Sterilisation pressure |
0.23 MPa |
|
Pressure resolution |
0.1 kPa |
|
Ultimate vacuum |
-0.096 MPa |
|
Temperature controller |
Microprocessor PID control |
|
Display |
LCD touchscreen |
|
Drying function |
Yes |
|
Drying time |
15 minutes |
|
Vacuum process |
Three-time pulsed vacuum |
|
Water injection |
Built-in water tank |
|
Power consumption |
3.6 kW |
|
Power supply |
220 V, 50 Hz |
|
Standard sterilisation shelf |
1 × stainless steel shelf |
|
Standard accessory |
Printer |
|
Net weight |
65 kg |
|
Gross weight |
120 kg |
|
Shipping dimensions (W × D × H) |
1150 × 700 × 700 mm |
Specifications above are based on the published technical data for model ST-B45B.
Suitable Healthcare and Laboratory Environments
The 45-litre benchtop format may be relevant to appropriately equipped healthcare and laboratory environments requiring steam sterilisation capability.
Potential environments include hospital decontamination services, laboratories, research facilities, clinical laboratories and other specialist facilities where the loads being processed are compatible with the validated sterilisation cycle.
Suitability should be assessed against the intended load, local decontamination policy, required standards, installation environment and relevant UK healthcare guidance.
The presence of a particular programme does not by itself establish that every instrument or material within that category is suitable for steam sterilisation. The instructions for use supplied with reusable medical devices should also be followed.
Benchtop Class B Autoclave 45L Compared with Other Steriliser Types
|
Feature |
ST-B45B Class B Autoclave |
Gravity Steam Steriliser |
Dry-Heat Steriliser |
|
Sterilisation method |
Pressurised steam with vacuum stages |
Steam |
Dry heat |
|
Capacity |
45 L |
Product dependent |
Product dependent |
|
Pre-vacuum |
Yes, three-time pulsed vacuum |
Generally not equivalent to Class B vacuum operation |
Not applicable |
|
Post-vacuum drying |
Yes |
Product dependent |
Not applicable in the same way |
|
Liquids programme |
Yes |
Product dependent |
Different process requirements |
|
Hollow instrument programme |
Yes |
Suitability varies |
Suitability varies |
|
Dressings programme |
Yes |
Product dependent |
Different process requirements |
|
Integrated printer |
Yes |
Product dependent |
Product dependent |
|
Water requirement |
Built-in water tank |
Usually required |
Not required for dry heat |
The appropriate sterilisation technology depends on the items being processed. NHS England guidance specifically advises purchasers to consider compatibility between the items being processed and the sterilisation process itself.
Procurement and Installation Considerations
Procurement of a steriliser requires consideration beyond chamber capacity and purchase specification.
The proposed installation location should be assessed for the necessary services. NHS England’s HTM 01-01 Part B identifies services that decontamination equipment may require, including electricity, water, drainage, ventilation and other utilities depending on the equipment. It advises purchasers to establish which services are required for the particular model and whether adequate capacity is available at the proposed installation site.
For the ST-B45B specifically, the verified electrical specification is 220 V, 50 Hz, with power consumption of 3.6 kW. The unit incorporates a built-in water tank.
Its 65 kg net weight and 870 × 600 × 520 mm external dimensions should also be considered when assessing bench capacity, positioning and handling requirements.
Important NHS Decontamination Considerations
The presence of Class B functionality does not by itself establish that a benchtop steriliser is suitable for every NHS decontamination pathway.
NHS England HTM 01-01 states that healthcare organisations should reduce inappropriate local reprocessing involving non-compliant or non-validated benchtop sterilisers. In acute-care surgical-instrument pathways, the guidance describes circumstances in which benchtop sterilisation should be a last resort and emphasises validation, testing, maintenance, audit and local procedures.
Healthcare organisations considering this equipment should therefore assess its proposed application against the relevant HTM guidance, local decontamination strategy and applicable standards before implementation.
Testing, Validation and Maintenance
Steam sterilisers used within healthcare decontamination require an appropriate programme of testing and maintenance.
HTM 01-01 Part C identifies responsibilities for testing and maintenance and describes the role of the Competent Person (Decontamination), including the competencies required for steriliser testing, maintenance, fault diagnosis and repair arrangements.
The ST-B45B includes dedicated BD Test and Vacuum Test programmes. These built-in programmes should be considered within the organisation’s wider validated testing and quality-management arrangements rather than treated as substitutes for required validation or maintenance.
Frequently Asked Questions
What capacity is the Benchtop Class B Autoclave?
The ST-B45B has a 45-litre chamber capacity.
What is the chamber size?
The chamber measures Ø316 × 590 mm.
What temperature range does the autoclave provide?
The specified sterilisation temperature range is 105–136°C, with a maximum working temperature of 136°C.
Does the ST-B45B have a vacuum system?
Yes. It incorporates a built-in vacuum pump providing a three-time pulsed vacuum process.
Does it have automatic drying?
Yes. Post-vacuum drying is incorporated, with a specified drying time of 15 minutes.
Does it have a built-in water tank?
Yes. The specified water injection method is a built-in water tank.
Does it include a printer?
Yes. A printer is listed as a standard accessory for the ST-B45B.
What programmes are available?
Published programmes include medical instruments, luminal instruments, dressings, rubber, liquids, BD testing and vacuum testing. Four user-customised programmes are also specified.
What material is the sterilisation chamber?
The chamber is specified as SUS304 stainless steel.
What is the power requirement?
The unit has a specified 3.6 kW power consumption and 220 V, 50 Hz power supply.
Does the autoclave have door safety protection?
Yes. An interlock prevents operation when the door is not properly locked and prevents opening while the chamber is pressurised.
Can it sterilise hollow instruments?
A dedicated luminal-instrument programme is specified. However, individual instruments should only be processed where their instructions for use confirm compatibility with the selected steam sterilisation process.
Is it suitable for NHS hospitals?
Suitability cannot be determined from the technical specification alone. NHS organisations need to assess the proposed installation and application against relevant decontamination guidance, validation requirements, local policies and the instruments or other loads being processed. NHS England HTM 01-01 provides specific guidance for reusable surgical instruments in acute care.
Further Information and Authoritative Sources
Niche Healthcare – Vertical Pulse Vacuum Autoclave:
https://www.nicheofficesolutions.co.uk/product/vertical-pulse-vacuum-autoclave/
NHS England – HTM 01-01: Management and Decontamination of Surgical Instruments Used in Acute Care:
https://www.england.nhs.uk/publication/decontamination-of-surgical-instruments-htm-01-01/
NHS England – HTM 01-01 Part B: Common Elements:
https://www.england.nhs.uk/wp-content/uploads/2021/05/HTM0101PartB.pdf
NHS England – HTM 01-01 Part C: Steam Sterilization:
https://www.england.nhs.uk/wp-content/uploads/2021/05/HTM0101PartC.pdf
Conclusion
The Benchtop Class B Autoclave 45L combines a 45-litre SUS304 stainless steel chamber with three-stage pulsed vacuum operation, automated steam sterilisation, post-vacuum drying and dedicated programmes for several compatible load types.
Its ST-B45B specification includes a 105–136°C sterilisation range, 0.23 MPa sterilisation pressure, LCD touchscreen, built-in water tank, integrated printer and multiple safety systems. For healthcare use, installation and operation should form part of an appropriately managed, validated and maintained decontamination process consistent with the relevant NHS guidance and the requirements of the items being processed.
Blog:
Autoclaves and Sterilisers for Healthcare and Laboratories
Published by Maisie McNamara | Clinical Marketing Team

Autoclaves & Sterilizers Infographic
See our full selection:
Healthcare Supplies in Aberdeen | Niche Healthcare
Healthcare Supplies in Basildon | Niche Healthcare
Healthcare Supplies in Basingstoke | Niche Healthcare
Healthcare Supplies in London | Niche Healthcare
For procurement details, bulk purchasing, and further product information, contact our team today on 01274 965089 or check out our website at www.nicheofficesolutions.co.uk / www.nicheofficesolutions.co.uk/niche-nhs
Further clinical information can be found on our blog page: www.nicheofficesolutions.co.uk/category/niche-healthcare-news
For products not found on our online website, please view our Healthcare catalogues: www.nicheofficesolutions.co.uk/healthcare-catalogues
View our Healthcare YouTube videos Playlist
If you have any additional questions, drop us an email at info@nicheofficesolutions.co.uk






Reviews
There are no reviews yet.