BB-100 Top grade neonatal Baby Incubator
Air mode and Baby mode controlled by micro-computer
Use AC Power and DC Power alternatively,DC12V or DC 24V Power on the ambulance
Set temperature, air temperature, baby temperature and internal battery voltage can be displayed
by LED separately
Double wall hood with side door
The bassinet can be pulled out easily
Natural air flow humidity, is adjustable continuously
The height of whole unit is adjustable
Oxygen cylinder and Oxygen supply system
LED observe light, adjustable brightness
Optional trolley
Ambulance type trolley
The inclination of infant bed is adjustable
Independent locking device for front door
Single wall hood, 4 operating windows and 2 iris ports, 3 infusion seals
Alarm functions: Power failure, over temperature, temperature deviation, fan failure, temperature sensor failure
37°C temperature set function
- Brand Name: Niche Healthcare
Model Number: NH-13095 - Power Source: Electric
- Warranty: 2 years
- After-sale Service: Online technical support
- Material: Acrylic, Metal, Plastic, Medical Plastic+ Aluminium
- Shelf Life: 2 years
- Quality Certification: Others
- Instrument classification: Class III
- Safety standard: Others
- Application: NICU, SCBU, NEONATAL, HDU
- MOQ: 1pc
- Function: Premature Care, Special Care, Pre-term, Term babies
Power Supply: |
~ 220V, 50/60Hz |
Power input: |
650VA(including power output socket :200VA) |
An ambient Temperature: |
20℃- 30℃ |
An ambient Humidity: |
30% RH – 75% RH |
An ambient air pressure: |
700 hPa -1060 hPa |
Air temperature : |
25℃-37℃, 37.1℃-38℃ |
The warm-up time: |
45 minutes |
-
Neonatal Incubator – A Lifesaving Equipment for Premature Babies
Introduction: Premature birth is a global healthcare challenge that requires specialized care and equipment to ensure the survival and well-being of the tiniest patients. Neonatal incubators, designed to create a controlled and nurturing environment, play a crucial role in providing the necessary support for premature babies. In this article, we’ll explore the significance of neonatal incubators and highlight their adherence to international standards such as CE and ISO.
The Importance of Neonatal Incubators: Neonatal incubators are specifically engineered to meet the unique needs of premature infants, who are born before completing a full-term pregnancy (37 weeks). These incubators serve several vital functions:
-
Temperature Control: Premature infants have underdeveloped thermoregulatory systems, making it essential to maintain a stable and warm environment. Neonatal incubators offer precise temperature control, ensuring the baby remains at an optimal body temperature.
-
Protection from Infection: Premature babies often have fragile immune systems. Incubators have sealed environments that prevent the entry of pathogens, helping reduce the risk of infections.
-
Respiratory Support: Some neonatal incubators are equipped with respiratory support systems such as CPAP (Continuous Positive Airway Pressure) to assist with breathing, vital for premature infants with underdeveloped lungs.
-
Monitoring: Neonatal incubators are fitted with advanced monitoring systems that keep a close watch on the baby’s vital signs, including heart rate, oxygen levels, and temperature.
CE and ISO Standards: To ensure the safety and effectiveness of neonatal incubators, they must adhere to stringent international standards. Two of the most notable standards in this regard are the CE (Conformité Européene) mark and the ISO (International Organization for Standardization) certification.
-
CE Marking: The CE mark is mandatory for medical devices, including neonatal incubators, that are intended to be sold within the European Economic Area. To earn this certification, the incubator must meet a range of criteria, including safety, performance, and quality assurance. Compliance with CE regulations guarantees that the product adheres to the highest standards of safety and efficacy.
-
ISO Certification: ISO standards, on the other hand, are internationally recognized quality management standards. Neonatal incubators can obtain ISO certification to demonstrate their adherence to a broad range of quality and safety requirements. The specific ISO standards applicable to medical devices may include ISO 9001 (Quality Management), ISO 13485 (Medical Devices Quality Management), and ISO 60601 (Medical Electrical Equipment).
Conclusion:
Neonatal incubators are indispensable tools in the care of premature babies. They create a protective and controlled environment that mimics the conditions of the womb, offering these fragile infants the best chance of survival and growth. Furthermore, the certification of these incubators with CE and ISO standards ensures that they meet the strictest criteria for safety and effectiveness, assuring parents, healthcare providers, and regulatory agencies that the well-being of these tiny patients is paramount. Neonatal incubators, in combination with these certifications, are a testament to our commitment to the welfare of our most vulnerable citizens, premature babies.
-
For more information, contact us 01274 965089 or check out our website at www.nicheofficesolutions.co.uk / www.nicheofficesolutions.co.uk/niche-nhs
Further clinical information can be found on our blog page: www.nicheofficesolutions.co.uk/category/niche-healthcare-news
For products not found on our online website, please view our Healthcare catalogues: www.nicheofficesolutions.co.uk/healthcare-catalogues
View our Healthcare YouTube videos Playlist
If you have any additional questions, drop us an email at info@nicheofficesolutions.co.uk
Reviews
There are no reviews yet.