Description
Nuclease-Free Water from Niche Healthcare is intended for sensitive molecular biology workflows where protecting DNA and RNA from nuclease activity is important. Nuclease-free water is used in laboratories working with nucleic acids because contaminating DNases and RNases can degrade DNA or RNA and potentially compromise downstream experimental results.
The term nuclease-free refers to water that is free from detectable DNase and RNase activity. This makes this water type relevant to molecular biology procedures such as PCR, qPCR, RT-PCR, cDNA synthesis, nucleic acid preparation, cloning and sequencing where an appropriate nuclease-free specification is required. Nebraska Energy Balance
Unlike general purified laboratory water, nuclease-free water should be selected specifically for workflows where nuclease contamination is a concern.
What Is Nuclease-Free Water?
Nucleases are enzymes that break down nucleic acids. DNases act on DNA, while RNases act on RNA.
Nuclease-free water is therefore water prepared and tested for use in applications where DNA or RNA integrity needs to be maintained. New England Biolabs defines nuclease-free water as water free of DNases and RNases and identifies it as appropriate for standard molecular biology applications. Nebraska Energy Balance
This distinction is particularly important for RNA work because unwanted RNase contamination can interfere with sensitive molecular biology procedures.
Nuclease-free water is also commonly described in laboratory environments as molecular biology grade water, RNase-free water, DNase-free water or PCR water, although these descriptions should only be considered equivalent where the individual product specification confirms the required characteristics. Merck Millipore
Why Nuclease-Free Water Matters
Water can form a substantial proportion of buffers, reagents and reaction mixtures used in molecular biology.
If the water introduces DNase or RNase activity, the nucleic acids being analysed can potentially be degraded. This can affect sample integrity, reproducibility and the reliability of downstream procedures.
Specialist molecular-biology guidance therefore recommends nuclease-free water when preparing samples, buffers and reagents for experiments involving DNA and RNA. Merck Millipore
This is fundamentally different from selecting laboratory water solely according to conductivity or resistivity. For nucleic-acid workflows, the absence of nuclease activity is an additional and application-specific requirement.
Nuclease-Free Water for PCR
PCR is one of the principal applications associated with nuclease-free water.
PCR reaction mixtures typically contain water alongside primers, nucleotides, polymerase, buffer, template DNA and other assay-specific components.
Because PCR can involve small quantities of nucleic acid, maintaining reagent quality and avoiding contamination are important considerations. Thermo Fisher notes that nuclease-free PCR water should be free from RNase and DNase activity and highlights the importance of avoiding nucleic-acid contamination that could contribute to false RT-PCR signals. Thermo Fisher Scientific
Nuclease-free water may therefore be used as an appropriate water component within PCR workflows where its product specification meets the requirements of the assay.
Nuclease-Free Water for qPCR
Quantitative PCR, or qPCR, combines amplification with real-time measurement and is used extensively within molecular biology research.
As with conventional PCR, the quality of reagents introduced into the reaction is important. Nuclease-free water is commonly used during preparation of qPCR reactions and appropriate sample dilutions.
Water used for qPCR should also be considered from a contamination-control perspective. “Nuclease-free” and “free from contaminating DNA” are not automatically identical claims, so laboratories performing particularly sensitive qPCR assays should select water whose complete specification meets the assay requirements.
Nuclease-Free Water for RT-PCR and RNA Work
RNA workflows require particular attention to RNase contamination.
RNases can degrade RNA and are an important contamination concern during RNA extraction, preparation and downstream analysis.
Nuclease-free water is consequently used extensively within reverse-transcription PCR (RT-PCR) and other RNA-based workflows. Specialist molecular-biology guidance recommends nuclease-free water when preparing samples and reagents for experiments involving nucleic acids. Merck Millipore
For highly sensitive RT-PCR applications, laboratories should determine whether the required water must also carry specific certification relating to genomic DNA or other contaminants.
cDNA Synthesis
Complementary DNA, or cDNA, is produced from an RNA template using reverse transcription.
Maintaining RNA integrity before and during this process is important because degradation of the original RNA can affect downstream analysis.
Nuclease-free water is routinely used in cDNA synthesis workflows. Commercial molecular-biology-grade nuclease-free waters are specifically documented for applications including cDNA synthesis and PCR amplification. MilliporeSigma
DNA and RNA Preparation
Nuclease-free water may also be used during appropriate DNA and RNA extraction, purification, dilution and preparation procedures.
Its role can include preparing reagents and buffers, diluting nucleic-acid samples and eluting nucleic acids where permitted by the relevant extraction or purification protocol.
The requirements of the specific extraction kit, purification method or validated laboratory procedure should always take precedence.
DNA Sequencing and Genomics
Sequencing workflows depend on the quality and integrity of nucleic-acid samples.
Nuclease-free water is commonly associated with DNA sequencing, RNA sequencing and broader genomics workflows because these applications involve preparation and manipulation of nucleic acids.
Specialist guidance identifies sequencing among the molecular biology procedures for which nuclease-free ultrapure water can be used. Merck Millipore
The complete water requirements should nevertheless be established for the specific sequencing platform, library-preparation kit or protocol being used.
Cloning and Gene Editing
Molecular cloning and gene-editing workflows involve multiple stages where DNA or RNA can be exposed to laboratory reagents.
Nuclease-free water can be used for appropriate sample, reagent and buffer preparation during these workflows. Specialist molecular-biology guidance identifies both cloning and gene editing among applications involving nuclease-free water. Merck Millipore
Suitability for a particular protocol should be assessed against its specific requirements.
Nuclease-Free Water for Electrophoresis
Nuclease-free molecular-biology water is also used within appropriate agarose gel electrophoresis workflows.
Commercially available molecular-biology-grade nuclease-free water is documented for use in PCR and electrophoresis, including preparation and manipulation of nucleic-acid samples. MilliporeSigma
Where water is being incorporated into electrophoresis buffers or other solutions, laboratories should follow the applicable laboratory protocol.
Suitable Laboratory Environments
Nuclease-Free Water may be relevant to laboratories working with DNA, RNA and other molecular biology procedures, including:
- Molecular biology laboratories
- Genomics laboratories
- Molecular diagnostics laboratories
- NHS pathology and specialist laboratory services
- University research laboratories
- Biomedical science departments
- Biotechnology laboratories
- Pharmaceutical research laboratories
- Genetics laboratories
- Microbiology research facilities
- Cancer research laboratories
- Academic research departments
Suitability should always be determined by the individual laboratory method rather than department type alone.
Product Specifications
|
Specification |
Product information |
|
Product |
Nuclease-Free Water |
|
Product type |
Molecular biology water |
|
Intended application category |
Nucleic-acid and molecular biology workflows |
|
DNase-free status |
Product-specific documentation should be checked |
|
RNase-free status |
Product-specific documentation should be checked |
|
DEPC treatment |
Not specified |
|
Sterility |
Not specified |
|
Filtration |
Not specified |
|
Endotoxin specification |
Not specified |
|
Protease-free status |
Not specified |
|
Genomic DNA-free status |
Not specified |
|
Resistivity |
Not specified |
|
Conductivity |
Not specified |
|
TOC |
Not specified |
|
pH |
Not specified |
|
Pack quantity / volume |
Not specified |
|
Shelf life |
Not specified |
Characteristics such as DEPC treatment, sterility, filtration level, endotoxin concentration and genomic-DNA contamination should not be inferred simply because a product is described as nuclease-free.
Nuclease-Free Water Compared with Other Laboratory Water Types
Different laboratory waters are designed around different quality requirements.
|
Water type |
Primary consideration |
Typical application context |
|
Nuclease-Free Water |
Absence of unwanted nuclease activity |
PCR, qPCR, RT-PCR and DNA/RNA workflows |
|
Type I ultrapure water |
Very high physicochemical purity |
HPLC, LC-MS, ICP-MS and sensitive analytical work |
|
Type II analytical water |
General analytical purity |
Buffers, reagents and routine laboratory applications |
|
Type III general lab water |
General laboratory water quality |
Glassware rinsing and compatible equipment feedwater |
|
Type IV pre-treated water |
Defined pre-treatment quality |
Water-treatment and appropriate process feedwater |
These categories address different requirements. Type I water should not automatically be assumed to be nuclease-free, just as nuclease-free water should not automatically be assumed to meet every Type I analytical-water parameter.
Laboratories should select water according to the complete requirements of the experiment.
Nuclease-Free Water Versus RNase-Free Water
“Nuclease-free” generally indicates absence of both RNase and DNase activity. New England Biolabs specifically defines nuclease-free water as water free of DNases and RNases. Nebraska Energy Balance
A product described only as “RNase-free” should not automatically be assumed to have been tested for DNase activity.
For procedures involving both DNA and RNA, the complete product specification should therefore be reviewed.
Nuclease-Free Water Versus DNase-Free Water
Similarly, water described only as DNase-free does not necessarily establish that it is also RNase-free.
Where the experiment requires protection against both DNase and RNase activity, water specifically verified for the relevant nuclease requirements should be selected.
Nuclease-Free Water Versus DEPC-Treated Water
Nuclease-free water and DEPC-treated water are not necessarily the same product.
Diethyl pyrocarbonate (DEPC) has historically been used in preparing nuclease-free water because it can inactivate RNases. However, nuclease-free water can also be produced without DEPC treatment. Merck Millipore
This distinction matters because residual DEPC can be undesirable in some molecular biology applications.
Thermo Fisher, for example, identifies non-DEPC-treated nuclease-free water as useful for procedures sensitive to residual DEPC and notes that DEPC is not recommended for some applications involving Tris buffer. Thermo Fisher Scientific
The DEPC status of the Niche Healthcare product should therefore be determined from its specific documentation rather than assumed.
Nuclease-Free Water Versus Type I Ultrapure Water
Type I ultrapure water and nuclease-free water address different aspects of laboratory water quality.
Type I specifications principally address physicochemical purity parameters. Nuclease-free specifications address the absence of unwanted enzymatic activity capable of degrading DNA or RNA.
An ultrapure water system may be capable of producing water suitable for molecular biology, but a Type I designation alone should not be treated as proof that the resulting water has been tested and certified free from DNase and RNase activity.
Where an experiment specifically requires nuclease-free water, laboratories should use water verified for that purpose.
Why DEPC Status Matters
When purchasing molecular-biology-grade water, procurement teams may see products advertised as either DEPC-treated or non-DEPC-treated.
Neither description should be assumed to be universally preferable.
Non-DEPC-treated water can be advantageous where residual DEPC could interfere with the intended procedure. Thermo Fisher specifically identifies applications such as oocyte injection as sensitive to residual DEPC and notes potential incompatibility considerations involving Tris. Thermo Fisher Scientific
The correct option should therefore be selected according to the requirements of the experimental protocol.
Procurement Considerations
Laboratory procurement teams sourcing nuclease-free water should establish the complete molecular-biology specification required by the end user.
Relevant questions include whether the water must be:
- DNase-free
- RNase-free
- Genomic-DNA-free
- Protease-free
- DEPC-treated or non-DEPC-treated
- Sterile
- Membrane-filtered
- Endotoxin-controlled
- Suitable for PCR or RT-PCR
- Suitable for sequencing
- Supplied with batch-specific quality documentation
These characteristics should be verified individually rather than inferred from the generic description “molecular biology water”.
For particularly sensitive diagnostic or research applications, laboratories should also establish any applicable validation, accreditation and quality-control requirements before introducing a new reagent.
Contamination Control During Use
Purchasing nuclease-free water is only one part of maintaining nuclease-free laboratory conditions.
Once a container has been opened, poor handling practices can introduce contamination. Molecular biology laboratories should therefore use appropriate clean laboratory techniques when dispensing and storing nuclease-free water.
Specialist guidance notes that preventing sample degradation requires attention not only to water but also to buffers, plasticware, glassware, benches and containers that may come into contact with DNA or RNA. Merck Millipore
Aliquoting may be appropriate within some laboratory workflows to reduce repeated access to a larger container, provided this is consistent with the laboratory’s procedures.
Frequently Asked Questions
What is Nuclease-Free Water?
Nuclease-Free Water is water intended for molecular biology procedures where unwanted DNase and RNase activity needs to be avoided. New England Biolabs defines nuclease-free water as free from DNases and RNases. Nebraska Energy Balance
What are nucleases?
Nucleases are enzymes that degrade nucleic acids. DNases act on DNA, while RNases act on RNA.
Why is nuclease-free water used for PCR?
PCR involves DNA and often small reaction volumes. Nuclease-free water helps avoid introducing enzymes capable of degrading nucleic acids. Specialist PCR-grade waters can additionally be tested for nucleic-acid contamination that could interfere with sensitive PCR or RT-PCR assays. Thermo Fisher Scientific
Can nuclease-free water be used for qPCR?
Nuclease-free water is commonly used in qPCR workflows. The water should meet all requirements of the particular assay, particularly where contamination with genomic DNA could affect results.
Can it be used for RT-PCR?
Nuclease-free water is relevant to RT-PCR and other RNA-based workflows because RNase contamination can compromise RNA integrity. Merck Millipore
Can nuclease-free water be used for cDNA synthesis?
Yes, nuclease-free water is commonly used in cDNA synthesis workflows. Commercial molecular-biology-grade nuclease-free waters are specifically documented for cDNA synthesis and PCR applications. MilliporeSigma
Can it be used for DNA and RNA dilution?
Nuclease-free water may be used for appropriate DNA and RNA dilution where permitted by the laboratory protocol.
Can nuclease-free water be used for sequencing?
Sequencing is an established application for molecular-biology-grade nuclease-free water. The requirements of the particular sequencing platform and library-preparation procedure should still be followed. Merck Millipore
Is nuclease-free water the same as distilled water?
No. Distillation describes a purification process. It does not automatically establish that the final water has been tested and verified free of DNase and RNase activity.
Is deionised water nuclease-free?
Not automatically. Deionisation removes ionic contaminants but does not by itself establish absence of DNase or RNase activity.
Is Type I ultrapure water automatically nuclease-free?
No. Type I and nuclease-free specifications address different water-quality characteristics. Where nuclease-free water is specifically required, that characteristic should be verified.
Is nuclease-free water always DEPC-treated?
No. Both DEPC-treated and non-DEPC-treated nuclease-free waters exist. Non-DEPC products are widely used in molecular biology. Thermo Fisher Scientific
Is nuclease-free water sterile?
Sterility should not be assumed solely from the term nuclease-free. Some commercial products are sterile-filtered or autoclaved, but this is a separate characteristic that should be verified for the individual product. Thermo Fisher Scientific
Is nuclease-free water endotoxin-free?
Not automatically. Endotoxin is a separate specification. Some specialist products carry defined endotoxin limits, but this should be verified rather than inferred from nuclease-free status. STEMCELL Technologies
Is nuclease-free water genomic-DNA-free?
Not necessarily. Thermo Fisher distinguishes PCR-grade water tested for genomic-DNA contamination in addition to nuclease activity. Laboratories requiring genomic-DNA-free water should therefore verify this characteristic specifically. Thermo Fisher Scientific
Can ordinary purified laboratory water be used instead?
Only where the procedure permits it. For nuclease-sensitive molecular biology procedures, water specifically verified as nuclease-free helps protect nucleic-acid integrity and reduce an avoidable source of experimental failure. Merck Millipore
Further Information and Authoritative Sources
Niche Healthcare – Nuclease-Free Water:
https://www.nicheofficesolutions.co.uk/product/nuclease-free-water/
Niche Healthcare – Type I Ultrapure Water:
https://www.nicheofficesolutions.co.uk/product/type-i-ultrapure-water/
New England Biolabs – What Does Nuclease-Free Refer to for Nuclease-Free Water?:
https://www.neb.com/en-gb/faqs/2016/10/24/what-does-nuclease-free-refer-to-for-nuclease-free-water
Thermo Fisher Scientific – Nuclease-Free Water:
https://www.thermofisher.com/ar/en/home/life-science/dna-rna-purification-analysis/rna-extraction/rna-extraction-products/nuclease-free-tubes-tips-and-buffers/nuclease-free-water.html
Merck – Water for Nuclease-Sensitive Molecular Biology Studies:
https://www.merckmillipore.com/GE/en/technical-documents/technical-article/genomics/dna-and-rna-purification/water-for-nuclease-sensitive-molecular-biology-studies
Conclusion
Nuclease-Free Water is an important laboratory reagent for molecular biology workflows where protecting DNA and RNA from unwanted nuclease activity is essential. Its applications can include PCR, qPCR, RT-PCR, cDNA synthesis, nucleic-acid preparation, sequencing, cloning and other DNA- or RNA-based procedures. Nebraska Energy Balance
Unlike general purified laboratory water, nuclease-free water is selected specifically because molecular biology workflows require control of DNase and RNase contamination. Laboratories should also consider whether their particular procedure requires additional verified characteristics such as genomic-DNA-free status, non-DEPC treatment, sterility, filtration or endotoxin control rather than assuming these properties from the nuclease-free designation alone.
Downloadable Resources:
Laboratory Water Specification Sheet
Published by Maisie McNamara | Clinical Marketing Team

Laboratory Water Infographic
See our full selection:
Healthcare Supplies in Aberdeen | Niche Healthcare
Healthcare Supplies in Basildon | Niche Healthcare
Healthcare Supplies in Basingstoke | Niche Healthcare
Healthcare Supplies in London | Niche Healthcare
For procurement details, bulk purchasing, and further product information, contact our team today on 01274 965089 or check out our website at www.nicheofficesolutions.co.uk / www.nicheofficesolutions.co.uk/niche-nhs
Further clinical information can be found on our blog page: www.nicheofficesolutions.co.uk/category/niche-healthcare-news
For products not found on our online website, please view our Healthcare catalogues: www.nicheofficesolutions.co.uk/healthcare-catalogues
View our Healthcare YouTube videos Playlist
If you have any additional questions, drop us an email at info@nicheofficesolutions.co.uk







Reviews
There are no reviews yet.