PFAS-Free Water

Niche Healthcare

Call For Pricing.

Model Number: NH-134561

SKU: NH-134561 - WTN1093501 Category: Tag:

Description

Focus keyword: PFAS-Free Water

SEO title: PFAS-Free Water for Trace & Ultra-Trace PFAS Analysis

Permalink: pfas-free-water

Meta description: PFAS-Free Water with total PFAS <5 ng/L for trace and ultra-trace PFAS analysis, environmental monitoring, blanks and laboratory testing.

PFAS-Free Water

PFAS-Free Water from Niche Healthcare is a high-purity environmental-grade reagent water specifically intended for trace and ultra-trace analysis of per- and polyfluoroalkyl substances (PFAS).

The published specification includes total PFAS <5 ng/L and **individual PFAS, including PFOA and PFOS, <1 ng/L**. The water also provides >18 MΩ/cm resistivity, Total Organic Carbon (TOC) <5 µg/L, bacteria <1 CFU/100 mL and endotoxin <0.03 EU/mL. Full batch traceability and a Certificate of Analysis are provided with every order. Niche Office Solutions Ltd

This specialist water is relevant to environmental laboratories, water and wastewater testing, research facilities, contract analytical laboratories and other organisations undertaking sensitive PFAS determination where contamination from laboratory water could compromise analytical results.

What Is PFAS-Free Water?

PFAS are a large group of synthetic chemicals known as per- and polyfluoroalkyl substances. Their persistence and widespread environmental occurrence have created a need for analytical methods capable of detecting individual PFAS at extremely low concentrations.

PFAS-Free Water provides laboratories with a controlled reagent-water source specifically manufactured for analytical workflows where background PFAS contamination needs to be minimised.

This is an important distinction from standard ultrapure water. A water product may have excellent general purity, resistivity and TOC characteristics without necessarily having a verified PFAS specification.

For this product, the published limits are:

Total PFAS: <5 ng/L

Individual PFAS, including PFOA and PFOS: <1 ng/L Niche Office Solutions Ltd

These defined limits allow laboratories to assess the water against their analytical method and required reporting limits rather than simply assuming that conventional ultrapure water is suitable.

Why PFAS-Free Water Matters

PFAS analysis presents particular contamination-control challenges because laboratories are often attempting to measure extremely low concentrations.

Water, solvents, reagents, sampling equipment, laboratory consumables and other materials used throughout the analytical process can potentially introduce unwanted PFAS.

The US Environmental Protection Agency’s PFAS analytical guidance specifically recognises this issue. EPA Method 1633A is used for analysis of PFAS in matrices including wastewater, surface water, groundwater, soil, biosolids, sediment, landfill leachate and tissue using LC-MS/MS. US EPA

EPA guidance also specifies the use of PFAS-free reagent water for applications including field blanks and equipment rinsing. US EPA

This demonstrates why reagent-water quality is an important part of PFAS contamination control rather than simply a general laboratory consumable consideration.

PFAS-Free Water Specifications

Specification

Product information

Product

PFAS-Free Water

Grade

Environmental

Resistivity

>18 MΩ/cm

Total Organic Carbon (TOC)

<5 µg/L

Total PFAS

<5 ng/L

Individual PFAS

<1 ng/L

PFOA / PFOS

Included within individual PFAS specification

Bacteria

<1 CFU/100 mL

Endotoxin

<0.03 EU/mL

Available volumes

100 ml to 27,000 litres

Batch traceability

Full batch traceability

Certificate of Analysis

Provided with every order

Shelf life

6 months when stored correctly

Chemical additives

None stated

Model number

NH-134561

SKU

NH-134561 – WTN1093501

These specifications are based on the published Niche Healthcare product information. Niche Office Solutions Ltd

PFAS-Free Water for Environmental Monitoring

Environmental monitoring is one of the primary applications for PFAS-Free Water.

PFAS testing can involve environmental matrices including surface water, groundwater, wastewater, soil, sediment, biosolids and other materials. EPA Method 1633A, for example, provides an LC-MS/MS method for determining 40 PFAS compounds across several environmental matrices. US EPA

In these workflows, reagent water can be used during laboratory preparation, quality-control procedures and contamination assessment.

Using water with defined PFAS limits can therefore help laboratories control one potential source of unwanted background contamination.

Water and Wastewater PFAS Analysis

PFAS contamination of water is an important area of environmental analysis.

The Drinking Water Inspectorate reports extensive monitoring of PFAS in England and Wales and notes that PFAS remain a significant focus because of their environmental persistence and potential impact on drinking-water sources. Drinking Water Inspectorate

PFAS-Free Water may be relevant to laboratories analysing:

  • Drinking water
  • Raw water
  • Groundwater
  • Surface water
  • Wastewater
  • Environmental water samples
  • Landfill leachate

The particular reagent-water requirements of the analytical method being followed should determine suitability.

PFAS-Free Water for Field Blanks

One particularly important use of PFAS-free reagent water is preparing field blanks.

Field blanks help assess whether contamination has been introduced during sampling, transport or handling rather than being genuinely present within the environmental sample.

EPA guidance describes preparing a field blank by transferring PFAS-free reagent water supplied by the laboratory into a sample container of the same type used for field samples. US EPA

This provides laboratories and sampling teams with a way to evaluate potential contamination associated with the field sampling process.

PFAS-Free Water for Equipment Blanks and Rinsing

PFAS-free water may also be used when assessing reusable sampling equipment.

EPA guidance states that where sample-collection equipment is cleaned and reused, an equipment blank can be prepared by pouring PFAS-free water over the cleaned equipment and collecting the resulting rinsate. US EPA

This can help determine whether equipment cleaning and handling procedures have introduced PFAS contamination.

The water itself must therefore have sufficiently controlled PFAS concentrations for the analytical requirements of the method.

PFAS-Free Water for Method Blanks

Method blanks are another important quality-control component of trace PFAS analysis.

A method blank can help laboratories determine whether contamination has been introduced by the analytical process, reagents, consumables or equipment.

EPA’s Method 1633 development documentation specifies PFAS-free water for preparing method blanks and associated quality-control samples. EPA NEPIS

The appropriate blank requirements should always follow the specific analytical method being performed.

PFAS-Free Water for LC-MS/MS Workflows

Liquid chromatography with tandem mass spectrometry (LC-MS/MS) is a major analytical technique used for targeted PFAS determination.

EPA Method 1633A uses LC-MS/MS for analysis of 40 PFAS compounds across several environmental matrices, while EPA Methods 533 and 537.1 are used for PFAS analysis in drinking water. US EPA

PFAS-Free Water may therefore form part of appropriate sample-preparation, blank or quality-control workflows associated with PFAS LC-MS/MS analysis where its specification satisfies the chosen method.

The product should not be described simply as “LC-MS grade water” for every LC-MS application, as its defining characteristic is its controlled PFAS specification.

PFOA and PFOS Testing

Two of the best-known PFAS compounds are perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS).

For this PFAS-Free Water, individual PFAS including PFOA and PFOS are specified at <1 ng/L. Niche Office Solutions Ltd

This individual-compound specification is particularly important because “total PFAS” and individual PFAS measurements represent different analytical considerations.

Laboratories should assess both the total and individual limits against the requirements of their method and required reporting limits.

PFAS-Free Water for Food Safety Testing

PFAS analysis is not restricted to water samples.

The Niche Healthcare product is also intended for applicable food-safety testing where PFAS determination forms part of the laboratory procedure. Niche Office Solutions Ltd

Suitability should be assessed against the particular extraction procedure, analytical method, matrix and quality-control requirements.

Suitable Laboratory Environments

PFAS-Free Water may be relevant to specialist environments including environmental testing laboratories, water and wastewater laboratories, contract analytical laboratories, university research laboratories, environmental research facilities, governmental laboratories and other organisations undertaking PFAS analysis.

The product may also be relevant to laboratories supporting environmental investigations or regulatory monitoring programmes.

Its suitability depends on whether the published PFAS limits and wider water-quality specification meet the requirements of the laboratory’s analytical method.

PFAS-Free Water Compared with Standard Ultrapure Water

PFAS-Free Water and conventional Type I ultrapure water should not automatically be considered interchangeable.

Characteristic

PFAS-Free Water

Standard Type I Ultrapure Water

High general water purity

Yes

Yes

High resistivity

>18 MΩ/cm for this product

Typically high

Defined TOC specification

<5 µg/L for this product

Product dependent

Defined total PFAS limit

<5 ng/L

Not necessarily specified

Defined individual PFAS limit

<1 ng/L

Not necessarily specified

Intended for PFAS testing

Yes

Not automatically

Field/equipment blank suitability

Depends on analytical method

Must have suitable PFAS control

Batch traceability

Yes for this product

Product dependent

Certificate of Analysis

Yes for this product

Product dependent

A laboratory should therefore not assume that water is suitable for PFAS analysis solely because it has high resistivity or is described as ultrapure.

PFAS-Free Water Versus Type I Ultrapure Water

The distinction is particularly important for laboratories already using Type I water.

Type I water is widely used for sensitive analytical techniques because of its high physicochemical purity. However, Type I classification does not by itself establish a specific PFAS concentration.

PFAS-Free Water addresses an additional requirement by providing defined limits for total and individual PFAS.

For laboratories undertaking trace or ultra-trace PFAS testing, the relevant consideration is therefore not simply whether water is “ultrapure”, but whether its PFAS background is sufficiently controlled and documented for the analytical method.

Understanding ng/L in PFAS Testing

PFAS concentrations are often discussed in nanograms per litre (ng/L) because analytical laboratories may be measuring extremely small concentrations.

One nanogram is one billionth of a gram.

The PFAS specification for this product is:

Total PFAS: <5 ng/L

Individual PFAS: <1 ng/L Niche Office Solutions Ltd

The reporting limit required for a particular project may differ, so laboratories should compare these specifications with the sensitivity and quality-control requirements of their analytical method.

Contamination Control During PFAS Analysis

PFAS contamination can arise from sources beyond the reagent water itself.

EPA analytical guidance notes that solvents, reagents, glassware and other sample-processing hardware can create artefacts or elevated analytical backgrounds. It also emphasises cleaning equipment to avoid PFAS cross-contamination and verifying disposable laboratory materials by batch or lot where appropriate. EPA NEPIS

This means PFAS-Free Water should form part of a wider contamination-control strategy rather than being considered sufficient on its own.

Laboratories should follow the procedures specified by their analytical method regarding containers, tubing, sample handling, consumables, solvents, equipment cleaning and quality-control samples.

Packaging and PFAS Analysis

Packaging is particularly important when dealing with PFAS-sensitive analytical workflows because contamination can potentially be introduced through inappropriate materials.

EPA Method 1633A guidance recommends that laboratories and sampling teams coordinate on sample containers and use materials that have been appropriately assessed for PFAS contamination. US EPA

The Niche Healthcare product is available with application-specific cap solutions and non-standard container options for specialist requirements. Niche Office Solutions Ltd

The packaging configuration should be selected according to the laboratory’s analytical method and contamination-control requirements.

Available Volumes and Bulk PFAS-Free Water

PFAS-Free Water is available in quantities ranging from 100 ml to 27,000 litres. Niche Office Solutions Ltd

This provides options for small analytical requirements, quality-control procedures, environmental sampling programmes and larger-scale specialist requirements.

Application-specific cap solutions, non-standard container types and custom labelling are also available. Niche Office Solutions Ltd

Batch Traceability and Certificate of Analysis

Full batch traceability is provided for this product, and a Certificate of Analysis is supplied with every order. Niche Office Solutions Ltd

This is particularly relevant for trace analytical work because laboratories may need to document the reagent-water batch associated with an analytical run or sampling programme.

Laboratories should review the applicable Certificate of Analysis against their method requirements and required reporting limits before use.

Procurement Considerations

PFAS-free reagent water should be procured according to the analytical method and required detection limits rather than simply by the description “PFAS-free”.

Important considerations include the total PFAS specification, individual PFAS limits, analytical method, required reporting limits, batch documentation, required volume, container material and cap configuration.

The laboratory should also establish whether the water is required for sample preparation, reagent preparation, field blanks, equipment blanks, rinsing or another quality-control purpose.

For highly sensitive work, packaging and laboratory consumables should be considered alongside water quality because PFAS contamination can arise from multiple sources.

Storage and Handling

The stated shelf life of this PFAS-Free Water is six months when stored correctly, and no chemical additives are stated. Niche Office Solutions Ltd

Appropriate handling is particularly important because introducing even small amounts of PFAS contamination could undermine the purpose of using controlled reagent water.

Containers should therefore be stored and handled according to the applicable product information and the laboratory’s PFAS contamination-control procedures.

Frequently Asked Questions

What is PFAS-Free Water?

PFAS-Free Water is high-purity reagent water specifically controlled for very low PFAS concentrations and intended for sensitive PFAS analytical workflows.

The Niche Healthcare product has a published total PFAS specification of <5 ng/L and individual PFAS specification of <1 ng/L. Niche Office Solutions Ltd

What does PFAS stand for?

PFAS stands for per- and polyfluoroalkyl substances, a large group of synthetic chemicals.

What is the total PFAS specification?

Total PFAS is specified at <5 ng/L. Niche Office Solutions Ltd

What is the individual PFAS specification?

Individual PFAS compounds, including PFOA and PFOS, are specified at <1 ng/L. Niche Office Solutions Ltd

What is the resistivity?

The published resistivity is >18 MΩ/cm. Niche Office Solutions Ltd

What is the TOC specification?

Total Organic Carbon is specified at <5 µg/L. Niche Office Solutions Ltd

What is the bacterial specification?

The published bacterial specification is <1 CFU/100 mL. Niche Office Solutions Ltd

What is the endotoxin specification?

Endotoxin is specified at <0.03 EU/mL. Niche Office Solutions Ltd

Can PFAS-Free Water be used for field blanks?

PFAS-free reagent water is specifically used for field blanks in EPA PFAS analytical guidance. The suitability of this particular product should be confirmed against the analytical method and required PFAS limits. US EPA

Can it be used for equipment blanks?

EPA guidance describes preparing equipment blanks using PFAS-free water where sampling equipment is cleaned and reused. US EPA

Can PFAS-Free Water be used for method blanks?

PFAS-free reagent water is used for method blanks within PFAS analytical methodologies. The laboratory should follow the requirements of the specific method being performed. EPA NEPIS

Can it be used for LC-MS/MS PFAS analysis?

PFAS-Free Water may be used in appropriate LC-MS/MS PFAS workflows where its specification meets the analytical method. EPA Method 1633A uses LC-MS/MS for targeted analysis of 40 PFAS compounds across multiple environmental matrices. US EPA

Is PFAS-Free Water the same as Type I ultrapure water?

Not necessarily. Standard Type I water can provide very high general purity without having a defined PFAS specification. Where PFAS-controlled reagent water is required, the actual PFAS limits should be verified.

Is ordinary deionised water suitable for PFAS analysis?

It should not automatically be assumed to be suitable. Water used for sensitive PFAS analysis should meet the requirements of the analytical method, including any required control of background PFAS.

What volumes are available?

The product is available from 100 ml to 27,000 litres. Niche Office Solutions Ltd

Is a Certificate of Analysis supplied?

Yes. A Certificate of Analysis is supplied with every order and full batch traceability is provided. Niche Office Solutions Ltd

Does the water contain chemical additives?

No chemical additives are stated. Niche Office Solutions Ltd

What is the shelf life?

The stated shelf life is six months when stored correctly. Niche Office Solutions Ltd

What Sizes Are Available?

Sizes up to 1000L are available in this product.

Further Information and Authoritative Sources

Niche Healthcare – PFAS-Free Water:
https://www.nicheofficesolutions.co.uk/product/pfas-free-water/

Niche Healthcare – Type I Ultrapure Water:
https://www.nicheofficesolutions.co.uk/product/type-i-ultrapure-water/

US Environmental Protection Agency – PFAS Analytical Methods for Environmental Matrices:
https://www.epa.gov/cwa-methods/cwa-analytical-methods-and-polyfluorinated-alkyl-substances-pfas

US Environmental Protection Agency – PFAS Drinking Water Laboratory Methods:
https://www.epa.gov/pfas/epa-pfas-drinking-water-laboratory-methods

Drinking Water Inspectorate – PFAS in Drinking Water:
https://www.dwi.gov.uk/what-we-do/annual-report/drinking-water-2025/drinking-water-2025-summary-of-the-chief-inspectors-report-for-drinking-water-in-england/perfluoroalkyl-and-polyfluoroalkyl-substances-pfas/

Conclusion

PFAS-Free Water provides environmental and analytical laboratories with a high-purity reagent-water source specifically intended for trace and ultra-trace PFAS determination.

Its published specification includes >18 MΩ/cm resistivity, <5 µg/L TOC, total PFAS <5 ng/L and individual PFAS including PFOA and PFOS <1 ng/L, alongside defined bacterial and endotoxin limits, full batch traceability and a Certificate of Analysis. Niche Office Solutions Ltd

The product may be particularly relevant to environmental monitoring, water and wastewater analysis, field and equipment blanks, laboratory quality-control procedures and other PFAS-sensitive workflows. Because PFAS analysis can be vulnerable to contamination from reagents, containers, equipment and consumables, laboratories should use the water as part of a wider method-specific contamination-control and quality-assurance process.

Downloadable Resources:

Laboratory Water Specification Sheet

Published by Maisie McNamara | Clinical Marketing Team

Laboratory Water Infographic

Laboratory Water Infographic

 

 

See our full selection:

Healthcare Supplies in Aberdeen | Niche Healthcare

Healthcare Supplies in Basildon | Niche Healthcare

Healthcare Supplies in Basingstoke | Niche Healthcare

Healthcare Supplies in London | Niche Healthcare

 

For procurement details, bulk purchasing, and further product information, contact our team today on 01274 965089 or check out our website at www.nicheofficesolutions.co.uk / www.nicheofficesolutions.co.uk/niche-nhs

Further clinical information can be found on our blog page: www.nicheofficesolutions.co.uk/category/niche-healthcare-news

For products not found on our online website, please view our Healthcare catalogues: www.nicheofficesolutions.co.uk/healthcare-catalogues

View our Healthcare YouTube videos Playlist

If you have any additional questions, drop us an email at info@nicheofficesolutions.co.uk 

Reviews

There are no reviews yet.

Be the first to review “PFAS-Free Water”

Your email address will not be published. Required fields are marked *