Description
Focus keyword: PFAS-Free Water
SEO title: PFAS-Free Water for Trace & Ultra-Trace PFAS Analysis
Permalink: pfas-free-water
Meta description: PFAS-Free Water with total PFAS <5 ng/L for trace and ultra-trace PFAS analysis, environmental monitoring, blanks and laboratory testing.
PFAS-Free Water
PFAS-Free Water from Niche Healthcare is a high-purity environmental-grade reagent water specifically intended for trace and ultra-trace analysis of per- and polyfluoroalkyl substances (PFAS).
The published specification includes total PFAS <5 ng/L and **individual PFAS, including PFOA and PFOS, <1 ng/L**. The water also provides >18 MΩ/cm resistivity, Total Organic Carbon (TOC) <5 µg/L, bacteria <1 CFU/100 mL and endotoxin <0.03 EU/mL. Full batch traceability and a Certificate of Analysis are provided with every order. Niche Office Solutions Ltd
This specialist water is relevant to environmental laboratories, water and wastewater testing, research facilities, contract analytical laboratories and other organisations undertaking sensitive PFAS determination where contamination from laboratory water could compromise analytical results.
What Is PFAS-Free Water?
PFAS are a large group of synthetic chemicals known as per- and polyfluoroalkyl substances. Their persistence and widespread environmental occurrence have created a need for analytical methods capable of detecting individual PFAS at extremely low concentrations.
PFAS-Free Water provides laboratories with a controlled reagent-water source specifically manufactured for analytical workflows where background PFAS contamination needs to be minimised.
This is an important distinction from standard ultrapure water. A water product may have excellent general purity, resistivity and TOC characteristics without necessarily having a verified PFAS specification.
For this product, the published limits are:
Total PFAS: <5 ng/L
Individual PFAS, including PFOA and PFOS: <1 ng/L Niche Office Solutions Ltd
These defined limits allow laboratories to assess the water against their analytical method and required reporting limits rather than simply assuming that conventional ultrapure water is suitable.
Why PFAS-Free Water Matters
PFAS analysis presents particular contamination-control challenges because laboratories are often attempting to measure extremely low concentrations.
Water, solvents, reagents, sampling equipment, laboratory consumables and other materials used throughout the analytical process can potentially introduce unwanted PFAS.
The US Environmental Protection Agency’s PFAS analytical guidance specifically recognises this issue. EPA Method 1633A is used for analysis of PFAS in matrices including wastewater, surface water, groundwater, soil, biosolids, sediment, landfill leachate and tissue using LC-MS/MS. US EPA
EPA guidance also specifies the use of PFAS-free reagent water for applications including field blanks and equipment rinsing. US EPA
This demonstrates why reagent-water quality is an important part of PFAS contamination control rather than simply a general laboratory consumable consideration.
PFAS-Free Water Specifications
|
Specification |
Product information |
|
Product |
PFAS-Free Water |
|
Grade |
Environmental |
|
Resistivity |
>18 MΩ/cm |
|
Total Organic Carbon (TOC) |
<5 µg/L |
|
Total PFAS |
<5 ng/L |
|
Individual PFAS |
<1 ng/L |
|
PFOA / PFOS |
Included within individual PFAS specification |
|
Bacteria |
<1 CFU/100 mL |
|
Endotoxin |
<0.03 EU/mL |
|
Available volumes |
100 ml to 27,000 litres |
|
Batch traceability |
Full batch traceability |
|
Certificate of Analysis |
Provided with every order |
|
Shelf life |
6 months when stored correctly |
|
Chemical additives |
None stated |
|
Model number |
NH-134561 |
|
SKU |
NH-134561 – WTN1093501 |
These specifications are based on the published Niche Healthcare product information. Niche Office Solutions Ltd
PFAS-Free Water for Environmental Monitoring
Environmental monitoring is one of the primary applications for PFAS-Free Water.
PFAS testing can involve environmental matrices including surface water, groundwater, wastewater, soil, sediment, biosolids and other materials. EPA Method 1633A, for example, provides an LC-MS/MS method for determining 40 PFAS compounds across several environmental matrices. US EPA
In these workflows, reagent water can be used during laboratory preparation, quality-control procedures and contamination assessment.
Using water with defined PFAS limits can therefore help laboratories control one potential source of unwanted background contamination.
Water and Wastewater PFAS Analysis
PFAS contamination of water is an important area of environmental analysis.
The Drinking Water Inspectorate reports extensive monitoring of PFAS in England and Wales and notes that PFAS remain a significant focus because of their environmental persistence and potential impact on drinking-water sources. Drinking Water Inspectorate
PFAS-Free Water may be relevant to laboratories analysing:
- Drinking water
- Raw water
- Groundwater
- Surface water
- Wastewater
- Environmental water samples
- Landfill leachate
The particular reagent-water requirements of the analytical method being followed should determine suitability.
PFAS-Free Water for Field Blanks
One particularly important use of PFAS-free reagent water is preparing field blanks.
Field blanks help assess whether contamination has been introduced during sampling, transport or handling rather than being genuinely present within the environmental sample.
EPA guidance describes preparing a field blank by transferring PFAS-free reagent water supplied by the laboratory into a sample container of the same type used for field samples. US EPA
This provides laboratories and sampling teams with a way to evaluate potential contamination associated with the field sampling process.
PFAS-Free Water for Equipment Blanks and Rinsing
PFAS-free water may also be used when assessing reusable sampling equipment.
EPA guidance states that where sample-collection equipment is cleaned and reused, an equipment blank can be prepared by pouring PFAS-free water over the cleaned equipment and collecting the resulting rinsate. US EPA
This can help determine whether equipment cleaning and handling procedures have introduced PFAS contamination.
The water itself must therefore have sufficiently controlled PFAS concentrations for the analytical requirements of the method.
PFAS-Free Water for Method Blanks
Method blanks are another important quality-control component of trace PFAS analysis.
A method blank can help laboratories determine whether contamination has been introduced by the analytical process, reagents, consumables or equipment.
EPA’s Method 1633 development documentation specifies PFAS-free water for preparing method blanks and associated quality-control samples. EPA NEPIS
The appropriate blank requirements should always follow the specific analytical method being performed.
PFAS-Free Water for LC-MS/MS Workflows
Liquid chromatography with tandem mass spectrometry (LC-MS/MS) is a major analytical technique used for targeted PFAS determination.
EPA Method 1633A uses LC-MS/MS for analysis of 40 PFAS compounds across several environmental matrices, while EPA Methods 533 and 537.1 are used for PFAS analysis in drinking water. US EPA
PFAS-Free Water may therefore form part of appropriate sample-preparation, blank or quality-control workflows associated with PFAS LC-MS/MS analysis where its specification satisfies the chosen method.
The product should not be described simply as “LC-MS grade water” for every LC-MS application, as its defining characteristic is its controlled PFAS specification.
PFOA and PFOS Testing
Two of the best-known PFAS compounds are perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS).
For this PFAS-Free Water, individual PFAS including PFOA and PFOS are specified at <1 ng/L. Niche Office Solutions Ltd
This individual-compound specification is particularly important because “total PFAS” and individual PFAS measurements represent different analytical considerations.
Laboratories should assess both the total and individual limits against the requirements of their method and required reporting limits.
PFAS-Free Water for Food Safety Testing
PFAS analysis is not restricted to water samples.
The Niche Healthcare product is also intended for applicable food-safety testing where PFAS determination forms part of the laboratory procedure. Niche Office Solutions Ltd
Suitability should be assessed against the particular extraction procedure, analytical method, matrix and quality-control requirements.
Suitable Laboratory Environments
PFAS-Free Water may be relevant to specialist environments including environmental testing laboratories, water and wastewater laboratories, contract analytical laboratories, university research laboratories, environmental research facilities, governmental laboratories and other organisations undertaking PFAS analysis.
The product may also be relevant to laboratories supporting environmental investigations or regulatory monitoring programmes.
Its suitability depends on whether the published PFAS limits and wider water-quality specification meet the requirements of the laboratory’s analytical method.
PFAS-Free Water Compared with Standard Ultrapure Water
PFAS-Free Water and conventional Type I ultrapure water should not automatically be considered interchangeable.
|
Characteristic |
PFAS-Free Water |
Standard Type I Ultrapure Water |
|
High general water purity |
Yes |
Yes |
|
High resistivity |
>18 MΩ/cm for this product |
Typically high |
|
Defined TOC specification |
<5 µg/L for this product |
Product dependent |
|
Defined total PFAS limit |
<5 ng/L |
Not necessarily specified |
|
Defined individual PFAS limit |
<1 ng/L |
Not necessarily specified |
|
Intended for PFAS testing |
Yes |
Not automatically |
|
Field/equipment blank suitability |
Depends on analytical method |
Must have suitable PFAS control |
|
Batch traceability |
Yes for this product |
Product dependent |
|
Certificate of Analysis |
Yes for this product |
Product dependent |
A laboratory should therefore not assume that water is suitable for PFAS analysis solely because it has high resistivity or is described as ultrapure.
PFAS-Free Water Versus Type I Ultrapure Water
The distinction is particularly important for laboratories already using Type I water.
Type I water is widely used for sensitive analytical techniques because of its high physicochemical purity. However, Type I classification does not by itself establish a specific PFAS concentration.
PFAS-Free Water addresses an additional requirement by providing defined limits for total and individual PFAS.
For laboratories undertaking trace or ultra-trace PFAS testing, the relevant consideration is therefore not simply whether water is “ultrapure”, but whether its PFAS background is sufficiently controlled and documented for the analytical method.
Understanding ng/L in PFAS Testing
PFAS concentrations are often discussed in nanograms per litre (ng/L) because analytical laboratories may be measuring extremely small concentrations.
One nanogram is one billionth of a gram.
The PFAS specification for this product is:
Total PFAS: <5 ng/L
Individual PFAS: <1 ng/L Niche Office Solutions Ltd
The reporting limit required for a particular project may differ, so laboratories should compare these specifications with the sensitivity and quality-control requirements of their analytical method.
Contamination Control During PFAS Analysis
PFAS contamination can arise from sources beyond the reagent water itself.
EPA analytical guidance notes that solvents, reagents, glassware and other sample-processing hardware can create artefacts or elevated analytical backgrounds. It also emphasises cleaning equipment to avoid PFAS cross-contamination and verifying disposable laboratory materials by batch or lot where appropriate. EPA NEPIS
This means PFAS-Free Water should form part of a wider contamination-control strategy rather than being considered sufficient on its own.
Laboratories should follow the procedures specified by their analytical method regarding containers, tubing, sample handling, consumables, solvents, equipment cleaning and quality-control samples.
Packaging and PFAS Analysis
Packaging is particularly important when dealing with PFAS-sensitive analytical workflows because contamination can potentially be introduced through inappropriate materials.
EPA Method 1633A guidance recommends that laboratories and sampling teams coordinate on sample containers and use materials that have been appropriately assessed for PFAS contamination. US EPA
The Niche Healthcare product is available with application-specific cap solutions and non-standard container options for specialist requirements. Niche Office Solutions Ltd
The packaging configuration should be selected according to the laboratory’s analytical method and contamination-control requirements.
Available Volumes and Bulk PFAS-Free Water
PFAS-Free Water is available in quantities ranging from 100 ml to 27,000 litres. Niche Office Solutions Ltd
This provides options for small analytical requirements, quality-control procedures, environmental sampling programmes and larger-scale specialist requirements.
Application-specific cap solutions, non-standard container types and custom labelling are also available. Niche Office Solutions Ltd
Batch Traceability and Certificate of Analysis
Full batch traceability is provided for this product, and a Certificate of Analysis is supplied with every order. Niche Office Solutions Ltd
This is particularly relevant for trace analytical work because laboratories may need to document the reagent-water batch associated with an analytical run or sampling programme.
Laboratories should review the applicable Certificate of Analysis against their method requirements and required reporting limits before use.
Procurement Considerations
PFAS-free reagent water should be procured according to the analytical method and required detection limits rather than simply by the description “PFAS-free”.
Important considerations include the total PFAS specification, individual PFAS limits, analytical method, required reporting limits, batch documentation, required volume, container material and cap configuration.
The laboratory should also establish whether the water is required for sample preparation, reagent preparation, field blanks, equipment blanks, rinsing or another quality-control purpose.
For highly sensitive work, packaging and laboratory consumables should be considered alongside water quality because PFAS contamination can arise from multiple sources.
Storage and Handling
The stated shelf life of this PFAS-Free Water is six months when stored correctly, and no chemical additives are stated. Niche Office Solutions Ltd
Appropriate handling is particularly important because introducing even small amounts of PFAS contamination could undermine the purpose of using controlled reagent water.
Containers should therefore be stored and handled according to the applicable product information and the laboratory’s PFAS contamination-control procedures.
Frequently Asked Questions
What is PFAS-Free Water?
PFAS-Free Water is high-purity reagent water specifically controlled for very low PFAS concentrations and intended for sensitive PFAS analytical workflows.
The Niche Healthcare product has a published total PFAS specification of <5 ng/L and individual PFAS specification of <1 ng/L. Niche Office Solutions Ltd
What does PFAS stand for?
PFAS stands for per- and polyfluoroalkyl substances, a large group of synthetic chemicals.
What is the total PFAS specification?
Total PFAS is specified at <5 ng/L. Niche Office Solutions Ltd
What is the individual PFAS specification?
Individual PFAS compounds, including PFOA and PFOS, are specified at <1 ng/L. Niche Office Solutions Ltd
What is the resistivity?
The published resistivity is >18 MΩ/cm. Niche Office Solutions Ltd
What is the TOC specification?
Total Organic Carbon is specified at <5 µg/L. Niche Office Solutions Ltd
What is the bacterial specification?
The published bacterial specification is <1 CFU/100 mL. Niche Office Solutions Ltd
What is the endotoxin specification?
Endotoxin is specified at <0.03 EU/mL. Niche Office Solutions Ltd
Can PFAS-Free Water be used for field blanks?
PFAS-free reagent water is specifically used for field blanks in EPA PFAS analytical guidance. The suitability of this particular product should be confirmed against the analytical method and required PFAS limits. US EPA
Can it be used for equipment blanks?
EPA guidance describes preparing equipment blanks using PFAS-free water where sampling equipment is cleaned and reused. US EPA
Can PFAS-Free Water be used for method blanks?
PFAS-free reagent water is used for method blanks within PFAS analytical methodologies. The laboratory should follow the requirements of the specific method being performed. EPA NEPIS
Can it be used for LC-MS/MS PFAS analysis?
PFAS-Free Water may be used in appropriate LC-MS/MS PFAS workflows where its specification meets the analytical method. EPA Method 1633A uses LC-MS/MS for targeted analysis of 40 PFAS compounds across multiple environmental matrices. US EPA
Is PFAS-Free Water the same as Type I ultrapure water?
Not necessarily. Standard Type I water can provide very high general purity without having a defined PFAS specification. Where PFAS-controlled reagent water is required, the actual PFAS limits should be verified.
Is ordinary deionised water suitable for PFAS analysis?
It should not automatically be assumed to be suitable. Water used for sensitive PFAS analysis should meet the requirements of the analytical method, including any required control of background PFAS.
What volumes are available?
The product is available from 100 ml to 27,000 litres. Niche Office Solutions Ltd
Is a Certificate of Analysis supplied?
Yes. A Certificate of Analysis is supplied with every order and full batch traceability is provided. Niche Office Solutions Ltd
Does the water contain chemical additives?
No chemical additives are stated. Niche Office Solutions Ltd
What is the shelf life?
The stated shelf life is six months when stored correctly. Niche Office Solutions Ltd
What Sizes Are Available?
Sizes up to 1000L are available in this product.
Further Information and Authoritative Sources
Niche Healthcare – PFAS-Free Water:
https://www.nicheofficesolutions.co.uk/product/pfas-free-water/
Niche Healthcare – Type I Ultrapure Water:
https://www.nicheofficesolutions.co.uk/product/type-i-ultrapure-water/
US Environmental Protection Agency – PFAS Analytical Methods for Environmental Matrices:
https://www.epa.gov/cwa-methods/cwa-analytical-methods-and-polyfluorinated-alkyl-substances-pfas
US Environmental Protection Agency – PFAS Drinking Water Laboratory Methods:
https://www.epa.gov/pfas/epa-pfas-drinking-water-laboratory-methods
Drinking Water Inspectorate – PFAS in Drinking Water:
https://www.dwi.gov.uk/what-we-do/annual-report/drinking-water-2025/drinking-water-2025-summary-of-the-chief-inspectors-report-for-drinking-water-in-england/perfluoroalkyl-and-polyfluoroalkyl-substances-pfas/
Conclusion
PFAS-Free Water provides environmental and analytical laboratories with a high-purity reagent-water source specifically intended for trace and ultra-trace PFAS determination.
Its published specification includes >18 MΩ/cm resistivity, <5 µg/L TOC, total PFAS <5 ng/L and individual PFAS including PFOA and PFOS <1 ng/L, alongside defined bacterial and endotoxin limits, full batch traceability and a Certificate of Analysis. Niche Office Solutions Ltd
The product may be particularly relevant to environmental monitoring, water and wastewater analysis, field and equipment blanks, laboratory quality-control procedures and other PFAS-sensitive workflows. Because PFAS analysis can be vulnerable to contamination from reagents, containers, equipment and consumables, laboratories should use the water as part of a wider method-specific contamination-control and quality-assurance process.
Downloadable Resources:
Laboratory Water Specification Sheet
Published by Maisie McNamara | Clinical Marketing Team

Laboratory Water Infographic
See our full selection:
Healthcare Supplies in Aberdeen | Niche Healthcare
Healthcare Supplies in Basildon | Niche Healthcare
Healthcare Supplies in Basingstoke | Niche Healthcare
Healthcare Supplies in London | Niche Healthcare
For procurement details, bulk purchasing, and further product information, contact our team today on 01274 965089 or check out our website at www.nicheofficesolutions.co.uk / www.nicheofficesolutions.co.uk/niche-nhs
Further clinical information can be found on our blog page: www.nicheofficesolutions.co.uk/category/niche-healthcare-news
For products not found on our online website, please view our Healthcare catalogues: www.nicheofficesolutions.co.uk/healthcare-catalogues
View our Healthcare YouTube videos Playlist
If you have any additional questions, drop us an email at info@nicheofficesolutions.co.uk








Reviews
There are no reviews yet.