Type IV Pre-treated Water
Type IV Pre-treated Water from Niche Healthcare, also labelled as Process Water, provides a ready-to-use purified water supply for general laboratory, technical and water-treatment applications where a defined pre-treated water quality is required.
The product is supplied to an ASTM D1193 Type IV specification, with stated resistivity of 0.2 MΩ, conductivity of 5 µS/cm, pH of 5.8, sodium of ≤50 µg/L and chloride of ≤50 µg/L. Full batch traceability and a Certificate of Analysis are provided. Niche Office Solutions Ltd
Available quantities range from 100 ml to 27,000 litres, providing flexibility for smaller requirements, contingency supplies, equipment feedwater and substantial bulk applications. Niche Office Solutions Ltd
What Is Type IV Pre-treated Water?
Type IV water is one of four reagent-water types defined by ASTM D1193.
ASTM explains that Type IV reagent water may be produced using processes including distillation, ion exchange, continuous electrodeionisation, reverse osmosis, electrodialysis or combinations of appropriate technologies, provided the required constituent specifications are achieved. ASTM Store
Importantly, ASTM states that the Type I, II, III and IV classifications reflect historical precedence and should not be interpreted simply as a progression in water purity. The appropriate water type should instead be selected according to its specification and intended application. ASTM Store
For this product, Type IV water is primarily intended for general laboratory infrastructure, technical processes and feedwater applications, rather than highly sensitive analytical testing.
Type IV Pre-treated Water Specifications
|
Specification |
Product information |
|
Water grade |
Type IV Pre-treated Water / Process Water |
|
Standard |
ASTM D1193 |
|
Resistivity |
0.2 MΩ |
|
Conductivity |
5 µS/cm |
|
pH |
5.8 |
|
Sodium |
≤50 µg/L |
|
Chloride |
≤50 µg/L |
|
Available volumes |
100 ml to 27,000 litres |
|
Batch traceability |
Full batch traceability |
|
Certificate of Analysis |
Provided |
|
Shelf life |
6 months when stored correctly |
|
Chemical additives |
None stated |
|
Model number |
NH-134559 |
|
SKU |
NH-134559 – WTN1093499 |
These are the published characteristics of the Niche Healthcare product. Niche Office Solutions Ltd
Why Use Type IV Pre-treated Water?
Water requirements differ considerably between laboratory processes and equipment.
Highly sensitive analytical techniques can require ultrapure Type I water because very small concentrations of contaminants may interfere with analytical measurements. General technical processes and feedwater applications often have very different requirements.
Type IV Pre-treated Water provides a defined water specification for compatible processes that do not require Type I or Type II water.
This can make Type IV water particularly relevant as feedwater for further purification processes and for selected non-critical technical applications where the equipment manufacturer permits its use.
Why Is It Also Called Process Water?
The product may be labelled Process Water because its intended applications include general technical and water-treatment processes.
“Process water” is a broad descriptive term rather than a substitute for the actual product specification. When assessing suitability, laboratories and procurement teams should therefore consider the measurable Type IV characteristics rather than relying solely on the wording used on the container.
For this product, the relevant published characteristics include 0.2 MΩ resistivity, 5 µS/cm conductivity, pH 5.8 and defined sodium and chloride limits. Niche Office Solutions Ltd
Type IV Pre-treated Water for Reverse Osmosis Feedwater
Reverse osmosis is widely used as part of laboratory and technical water-treatment systems.
The Niche Healthcare Type IV product can be considered as feedwater for compatible reverse osmosis systems where its published specification satisfies the incoming water requirements of the equipment. Niche Office Solutions Ltd
RO systems can differ significantly in their permissible feedwater conditions. Factors beyond conductivity may also influence suitability and system performance.
The water requirements specified by the particular reverse-osmosis system manufacturer should therefore be checked before use.
Feedwater for Deionisation Systems
Type IV Pre-treated Water can also provide feedwater for compatible deionisation systems. Niche Office Solutions Ltd
Deionisation systems remove ionic contaminants from water through ion-exchange or related technologies. Feeding these systems with appropriately pre-treated water can form one stage of a broader laboratory water-purification process.
However, the Type IV classification alone should not be treated as confirmation of compatibility with every deionisation system. The required incoming-water specification should be checked for the individual equipment.
Feedwater for Distillation Systems
Distillation feedwater is another stated application for this Type IV product. Niche Office Solutions Ltd
Distillation involves vaporising water and subsequently condensing the resulting vapour as part of the purification process.
Type IV water can provide a defined pre-treated supply for compatible distillation systems where its specification meets the requirements established for the equipment.
Type IV Water for Cooling Circuits
Type IV Pre-treated Water may also be used within compatible cooling circuits requiring an appropriately specified pre-treated water supply. Niche Office Solutions Ltd
Cooling equipment can have its own requirements relating to water chemistry, corrosion, mineral deposition and microbial management.
For that reason, Type IV water should not automatically be introduced into every cooling system simply because it is purified. The equipment or system specification should determine the required water quality.
Non-Critical Condenser Applications
The product is also intended for appropriate non-critical condenser applications. Niche Office Solutions Ltd
Using water with a controlled specification can provide a more defined input than an uncontrolled water source where a technical process requires pre-treated water.
As with cooling circuits, compatibility should be assessed against the condenser manufacturer’s requirements and the wider operating conditions of the system.
Type IV Pre-treated Water in Laboratory and Healthcare Environments
Within laboratories and healthcare facilities, Type IV water is primarily relevant to infrastructure, equipment and water-treatment processes rather than direct use in sensitive analytical testing.
Potential environments include hospital laboratories, NHS pathology services, university laboratories, research facilities, pharmaceutical organisations, biotechnology facilities, analytical laboratories and scientific or technical facilities operating compatible water-treatment equipment.
Actual suitability depends on the process or equipment specification rather than the department in which the water is being used.
Type I, Type II, Type III and Type IV Water Compared
Laboratory and technical water grades should be selected according to the required specification and application.
|
Water grade |
General application context |
Typical application examples |
|
Type I |
Critical ultrapure applications |
HPLC, LC-MS, ICP-MS and other sensitive analytical techniques |
|
Type II |
General analytical laboratory applications |
Reagent and buffer preparation and appropriate laboratory equipment |
|
Type III |
General laboratory and equipment applications |
Glassware rinsing, compatible autoclave feedwater and purification-system feedwater |
|
Type IV |
General technical and pre-treatment applications |
Cooling circuits and feedwater for RO, deionisation and distillation |
ASTM D1193 specifies four reagent-water types and expressly cautions that their numbering should not be regarded simply as a ranking of water purity. ASTM Store
The most appropriate grade is therefore the one whose characteristics satisfy the requirements of the process.
Type IV Water Versus Type III General Lab Water
Type III and Type IV water can both form part of laboratory infrastructure, but they have different published specifications.
The Niche Healthcare Type III General Lab Water has a published resistivity of 4 MΩ and conductivity of 0.25 µS/cm, while this Type IV Pre-treated Water has a resistivity of 0.2 MΩ and conductivity of 5 µS/cm.
Type III is positioned for applications including compatible glassware washers, autoclave feedwater and pure-steam generation, while Type IV is intended principally for general technical operations and feedwater for further purification.
The intended equipment or process should determine which specification is appropriate.
Type IV Water Versus Ordinary Mains Water
A significant difference between Type IV reagent water and ordinary mains water is that Type IV water is supplied to a defined laboratory reagent-water specification.
Mains water is produced for potable water requirements rather than ASTM reagent-water specifications and its mineral and ionic composition can vary according to source and treatment.
Where equipment requires a defined pre-treated feedwater specification, an ASTM Type IV product can therefore provide a controlled alternative.
This does not mean Type IV water is required for every piece of laboratory equipment. The manufacturer’s feedwater specification remains the appropriate reference.
ASTM Type IV Water and ISO 3696
ASTM D1193 and ISO 3696 are separate laboratory-water standards.
ISO 3696 specifies three grades of water for the analysis of inorganic chemicals. ISO states that the standard does not apply to organic trace analysis, analysis of surface-active agents, or biological or medical analysis. The 1987 edition was reviewed and confirmed in 2023 and remains current. ISO
ASTM D1193, by comparison, specifies four reagent-water types, including Type IV. ASTM Store
An ASTM Type IV specification should therefore not automatically be described as equivalent to a particular ISO 3696 grade.
Ready-to-Use Type IV Water Versus On-Site Treatment
Laboratories and technical facilities may either produce pre-treated water internally or procure it as a ready-to-use supply.
|
Consideration |
Ready-to-use Type IV water |
On-site water treatment |
|
Treatment equipment required |
Not required for supplied water |
Required |
|
Available quantity |
100 ml to 27,000 L for this product |
Depends on system output |
|
Batch traceability |
Provided |
Managed internally |
|
Certificate of Analysis |
Provided for supplied product |
Depends on internal testing arrangements |
|
Treatment-system maintenance |
Not required to produce supplied water |
Required |
|
Contingency use |
Can provide an alternative supply |
Dependent on system availability |
|
Point-of-use production |
No |
Yes |
|
Bulk supply |
Available |
Depends on equipment capacity |
A ready-to-use supply can be particularly relevant during purification-system maintenance, temporary projects, periods of increased demand or where producing the required water specification on site is impractical.
Available Volumes and Bulk Type IV Water
The product is available in quantities ranging from 100 ml to 27,000 litres. Niche Office Solutions Ltd
This range enables the same Type IV water specification to support smaller technical requirements and substantial bulk-water demand.
Application-specific cap solutions, non-standard container formats and custom labelling are also available for specialist requirements. Niche Office Solutions Ltd
Batch Traceability and Certificate of Analysis
Full batch traceability is provided, enabling individual supplied batches to be identified.
A Certificate of Analysis is also provided, giving laboratories and technical organisations documented information relating to the supplied water batch. Niche Office Solutions Ltd
Where the water will be used as equipment feedwater, the relevant specification and Certificate of Analysis should be reviewed against the requirements of the equipment or process.
Procurement Considerations
Procurement of process and laboratory water should begin with the technical requirement rather than simply the description “purified water”.
Useful parameters include required conductivity, resistivity, pH, sodium, chloride, volume, packaging format, storage requirements and intended application.
For this product, procurement teams can specify quantities from 100 ml to 27,000 litres, while full batch traceability and a Certificate of Analysis support documentation requirements. Niche Office Solutions Ltd
Where Type IV water will be used as feedwater, the equipment manufacturer should be consulted to establish the permitted incoming-water specification.
Storage and Handling
The published shelf life is six months when stored correctly, and no chemical additives are stated. Niche Office Solutions Ltd
Water quality can change through inappropriate storage or contamination during handling and dispensing. Containers should therefore be stored and handled in accordance with the applicable product information.
Where the supplied water specification is important to a process, contamination should be minimised during transfer and dispensing.
Frequently Asked Questions
What is Type IV Pre-treated Water?
Type IV Pre-treated Water is reagent water intended for appropriate general laboratory and technical applications. This product is supplied to a stated ASTM D1193 Type IV specification. Niche Office Solutions Ltd
Why is the product labelled Process Water?
Process Water is an alternative description used for this product because its applications include general technical processes and feedwater for further water treatment.
What is the resistivity?
The published resistivity is 0.2 MΩ. This corresponds with the ASTM Type IV minimum resistivity specified in the ASTM D1193 reference data. Niche Office Solutions Ltd
What is the conductivity?
The published conductivity is 5 µS/cm. ASTM’s Type IV specification also identifies 5 µS/cm at 25°C as the maximum electrical conductivity. Niche Office Solutions Ltd
What is the pH?
The product’s published pH is 5.8. ASTM D1193 specifies a pH range of 5.0–8.0 for Type IV reagent water. Niche Office Solutions Ltd
What are the sodium and chloride specifications?
Sodium and chloride are both specified at ≤50 µg/L. Niche Office Solutions Ltd
Can Type IV water be used as reverse-osmosis feedwater?
Reverse-osmosis feedwater is a stated application for this product. The requirements of the particular RO system should be checked before use. Niche Office Solutions Ltd
Can Type IV water be used with deionisation systems?
Yes, feedwater for compatible deionisation systems is a stated application. Equipment-specific requirements should still be confirmed. Niche Office Solutions Ltd
Can it be used as distillation feedwater?
Yes. Distillation-system feedwater is one of the stated applications, subject to compatibility with the individual system. Niche Office Solutions Ltd
Can Type IV water be used in cooling circuits?
Compatible cooling circuits are a stated application. The cooling-system manufacturer’s water-quality requirements should be checked before use. Niche Office Solutions Ltd
Is Type IV water suitable for HPLC?
Type IV water should not generally be substituted for the high-purity water specified for sensitive analytical applications such as HPLC. The analytical method and instrument requirements should determine the water specification.
Is Type IV water suitable for LC-MS or ICP-MS?
Type IV pre-treated water is intended for general technical and feedwater applications rather than highly sensitive LC-MS or ICP-MS analysis. These analytical techniques commonly require substantially higher-purity water.
Is Type IV water the same as deionised water?
No automatic equivalence should be assumed. Deionisation is a purification process, whereas ASTM Type IV describes a reagent-water specification. ASTM states that Type IV water may be produced using several technologies, including ion exchange, reverse osmosis, electrodialysis and distillation. ASTM Store
Is ASTM Type IV the same as ISO 3696 Grade 3?
No. ASTM D1193 and ISO 3696 are separate standards. ISO 3696 defines three grades, while ASTM D1193 defines four reagent-water types. ASTM Store
What volumes are available?
Available quantities range from 100 ml to 27,000 litres. Niche Office Solutions Ltd
Is a Certificate of Analysis provided?
Yes. A Certificate of Analysis and full batch traceability are provided. Niche Office Solutions Ltd
Does the water contain chemical additives?
No chemical additives are stated. Niche Office Solutions Ltd
What is the shelf life?
The stated shelf life is six months when stored correctly. Niche Office Solutions Ltd
Further Information and Authoritative Sources
Niche Healthcare – Type IV Pre-treated Water:
https://www.nicheofficesolutions.co.uk/product/type-iv-pre-treated-water/
Niche Healthcare – Type III General Lab Water:
https://www.nicheofficesolutions.co.uk/product/type-iii-general-lab-water/
Niche Healthcare – Type II Analytical Water:
https://www.nicheofficesolutions.co.uk/product/type-ii-analytical-water/
Niche Healthcare – Type I Ultrapure Water:
https://www.nicheofficesolutions.co.uk/product/type-i-ultrapure-water/
ASTM International – ASTM D1193 Standard Specification for Reagent Water:
https://store.astm.org/d1193-06r18.html
International Organization for Standardization – ISO 3696:1987, Water for Analytical Laboratory Use:
https://www.iso.org/standard/9169.html
Conclusion
Type IV Pre-treated Water provides laboratories, healthcare facilities and technical organisations with a defined ready-to-use water supply for appropriate general operations and water-treatment feed applications.
The product’s published specification includes 0.2 MΩ resistivity, 5 µS/cm conductivity, pH 5.8, ≤50 µg/L sodium and ≤50 µg/L chloride, together with full batch traceability and a Certificate of Analysis. Quantities ranging from 100 ml to 27,000 litres support requirements from smaller applications to substantial bulk-water supply. Niche Office Solutions Ltd
Type IV water is particularly relevant to compatible cooling circuits and as feedwater for reverse osmosis, deionisation and distillation systems. Selection should be based on the complete requirements of the individual equipment or process rather than the Type IV designation alone.
Downloadable Resources:
Laboratory Water Specification Sheet
Published by Maisie McNamara | Clinical Marketing Team

Laboratory Water Infographic
See our full selection:
Healthcare Supplies in Aberdeen | Niche Healthcare
Healthcare Supplies in Basildon | Niche Healthcare
Healthcare Supplies in Basingstoke | Niche Healthcare
Healthcare Supplies in London | Niche Healthcare
For procurement details, bulk purchasing, and further product information, contact our team today on 01274 965089 or check out our website at www.nicheofficesolutions.co.uk / www.nicheofficesolutions.co.uk/niche-nhs
Further clinical information can be found on our blog page: www.nicheofficesolutions.co.uk/category/niche-healthcare-news
For products not found on our online website, please view our Healthcare catalogues: www.nicheofficesolutions.co.uk/healthcare-catalogues
View our Healthcare YouTube videos Playlist
If you have any additional questions, drop us an email at info@nicheofficesolutions.co.uk