Description
Alarm function:
- Power failure, Over temperature, Temperature deviation, Fan failure, Temperature sensor failure
- Double wall hood with side door and front door, 4 operating windows and 2 iris ports, 5 infusion seals
- The infant bed can be pulled out from side door easily
- Natural air flow humidity
- The height od whole unit is adjustable
- Oxygen supply system
- LED observe light, adjustable brightness
- Built-in storage cabinet
Technical data
- Power supply: AC110/220V 60/50Hz
- Power input: 450VA
- Environment temperature: 10℃~30℃
- Operating condition, Environment relative humidity: 30%~75%
- Environment air velocity of flow: <1m/s
- Air temperature control range: 25℃~37℃ 37.1℃~38℃
- Skin temperature control range: 32℃~37℃ 37.1℃~38℃
- Air/Skin temperature sensor accuracy: ±0.3℃
- Temperature fluctuation: ±1℃
- Uniformity of mattress temperature: ≤1.5℃
- Air temperature deviation alarm: ±3℃
- Skin temperature deviation alarm: ±1℃
- Warm-uptime: ≤40min
- Internal noise level: ≤60dB(A)
- Main battery: DC12V 40AH,Li-ion battery
- Charge time: 12hours
- Battery use time: 2hours
- Auxiliary battery: DC8.4V 0.17AH,Li-ion battery
- Mattress size: 63cm(L)*32cm(W)
- Trough capacity: 1200mL
- Air filter: 0.5μm
Transport and storage
- Package: Each unit is packed in two plywood cases
- 100*70*88cm (control unit)
- N.W.:65Kg – G.W.:110Kg
- Trolley: 202*67*46cm
- N.W.:30Kg – G.W.:60Kg
- Environment temperature: -40℃~+55℃
- Environment relative humidity: ≤95%
- Atmospheric Pressure: 500~1060hpa
Standard configuration
- Main body (including the Transparent hood, Double hood, Control system, Infant bed, Water trough, Skin temperature sensor & two Oxygen cylinders)
- I.V.pole, Mattress & Observe
Standard configuration
- Main body (including the Transparent hood, Double hood, Control system, Infant bed, Water trough, Skin temperature sensor & two Oxygen cylinders.)
- I.V.pole, Mattress & Observe light.

Due to premature babies lacking body fat, they are less able to regulate body temperature, hence the use of an incubator.
NNAP Audit report 2021: https://www.rcpch.ac.uk/sites/default/files/2022-10/nnap_summary_report_on_2021_data.pdf
For more information, contact us 01274 965089 or check out our website at www.nicheofficesolutions.co.uk / www.nicheofficesolutions.co.uk/niche-nhs
Further clinical information can be found on our blog page: www.nicheofficesolutions.co.uk/category/niche-healthcare-news
For products not found on our online website, please view our Healthcare catalogues: www.nicheofficesolutions.co.uk/healthcare-catalogues
View our Healthcare YouTube videos Playlist
If you have any additional questions, drop us an email at info@nicheofficesolutions.co.uk